SAFETY PRECAUTIONS
• Follow the manufacturer's instructions.
• The installation team must check the correct installation and functioning of the equipment.
• Only use the product for the permitted uses specifi ed. Do not use the product for purposes other than those
specifi ed.
• Do not tamper with or modify the product.
• Only use original spare parts.
• Cordon off the working area to prevent the access of unauthorised persons.
• Ensure that the working area is clear of obstacles and the fl oor is not slippery.
• All equipment used must be in good working condition.
• Ensure that the work area is well lit. Ensure that the work area is free from obstructions and health and safety hazards.
• Do not allow unauthorised persons into the work area.
• Ensure that someone is present in the work area at all times. Do not leave the area and equipment unattended.
1.1

PRODUCT DESCRIPTION

RSK24 2000/2500 - microprocessor unit for driving one or two motors with total maximum power rating of 100 Watt.
This unit is available in two versions: for the Aprimatic RAIDER 2000 operator and for the Aprimatic RAIDER 2500
operator.
The difference between the two versions is that the default settings for some of the operating parameters are different
(see section 4).
Both versions can be supplied with a radio receiver already plugged into the board.
Operator functions can be set to match user needs. This is done by modifying the operating parameters as described in
section 4.1 "Advanced Programming".
1.2

PERMITTED USES AND APPLICATIONS

The RSK24 2000/2500 electronic unit has been designed for
the automatic control of Aprimatic RAIDER 2000 and RAIDER
2500 operators for single- and double-wing gates.
You should note the operating restrictions specifi ed in the
installation manual supplied with your operator.
Information
Only use the product for the permitted uses
specifi ed. Do not use the product for purposes other
than those specifi ed.
Do not tamper with or modify the product.
The product must only be installed using APRIMATIC
material.
Aprimatic S.p.A. declines all liability for damages caused
by failure to follow these instructions
1.3
TECHNICAL DATA (Tab. 1)
Technical specifi cations
Power supply voltage for accessories
Frequency
Power consumption (no load)
Power consumption (Max.)
Operating temperature
Storage temperature
Relative humidity
Protection class
F1 - primary transformer protection fuse
F2 - external accessories protection fuse (24 V DC)
F3- electronic circuit protection fuse
RSK24-2000/2500
230 V AC (+6 % ; -10 %)
50/60 Hz
3 W
100 W
(with 2 motors and accessories connected up and operating)
-20°C +55°C
-20°C +85°C
<90% non condensing
IP44 (only with IP44 housing)
3.15 A fast blow
500 mA fast blow
5 A fast blow
- 15 -