Container
Solvent and oil-based media: Observe local regulations. Only use conductive metal containers, placed on an earthed
surface such as concrete.
NOTE:
Do not place the container on any non-conductive surfaces such as paper or cardboard, as these can interfere with
earthing continuity.
Operation
Procedure for relieving pressure
1.
Turn power OFF. Wait 7
seconds for power to dissi-
pate.
Earthing a metal container
Connect one end of an earthing wire to the container and the other end to a good
earthing point, such as a water pipe.
Power requirements
Use an extension cable with an undamaged earthing contact. If an extension cable is
necessary, use a 3-wire, 12 AWG cable (2.5 mm2) at the very least.
Earthing contact when flushing or relieving pressure
Hold a metal part of the spray gun firmly to the side of an earthed metal container.
Then trigger the gun.
2.
Lock gun trigger safety.
Remove guard and nozzle.
3.
Turn pressure to lowe-
st setting. Trigger gun to
relieve pressure.
135
4.
Place the drain tube in the
container. Turn the suction
valve to the DRAIN positi-
on (vertical).