N.
Read/ Write
108
R/W
109
W
111
R/W
114
R/W
115
R/W
117
R/W
120
R/W
121
R/W
122
R/W
123
Reserved to Agilent service
124
125
R/W
126
R/W
130
Reserved to Agilent service
Turbo-V 3K-G Pumping System User Manual / 87-901-011-01
RS 232/RS 485 Communication Description
Data
Description
Type
N
Baud rate
L
Pump life/ cycle time/ cycle
number reset
L
Analog output type: output voltage
signal proportional to frequency or
power
N
Purge gas type
L
Threshold flowmeter
N
Low speed setting (Hz)
N
High speed setting (Hz)
N
Maximum excitation frequency in
Hz (active only in Stop condition)
L
Set vent valve open/close (N.C.)
L
Valves operating mode
N
Vent valve opening delay
(expressed in 0.2 sec)
Technical Information
Admitted
Values
600 = 0
1200 = 1
2400 = 2
4800 = 3
9600 = 4
(default = 4)
To reset write '1'
0 = frequency
1 = power
(default = 0)
0 = N
2
1 = Ar
sccm
510 to win. 121
(default = 510)
510 to win. 121
(default = 530)
510 to 530
(default = 530)
1 = open
0 = close
(default = 0)
0 = Controlled Vent
Procedure (default)
1 = on command
(see win.146)
0 to 65535
(corresponding to 0
to 13107 sec)
(default = 1)