To activate the Energy Manager function, select the "E-Manager" item and press
the "Enter" key.
When the "Energy Manager" function is running, the "Energy Manager" symbol
will appear in the top left corner of the display:
To deactivate the Energy Manager function, select a different function (ALL /
Permanent / OFF / ON) and press the "Enter" key.
NOTE!
Notes on setting up the switch-on and switch-off points
If the difference between the switch-on and switch-off points is too small, or if
there are fluctuations in effective power, the result may be multiple switching
cycles.
To avoid switching on and off frequently, the difference between the switch-on
and switch-off points should be at least 100 - 200 W.
When choosing the switch-off point, the power consumption of the connected
consumer should be taken into account.
When choosing the switch-on point, the weather conditions and anticipated in-
solation should be taken into account.
Application example
Switch-on point = 2000 W, switch-off point = 1800 W
If the inverter is outputting 2000 W or above, then the floating switch contact on
the inverter is switched on.
If the inverter output falls to below 1800 W, the floating switch contact is
switched off.
This allows useful applications, such as operating a heat pump or an air-condi-
tioning system using as much self-generated power as possible, to be implemen-
ted quickly

Time / Date

Set the time, date, the display format and automatic changeover between sum-
mer and winter time
Setting range
Set time
Set the time (hh:mm:ss or hh:mm am/pm – depending on the setting for the
time display format)
Set date
Set the date (dd.mm.yyyy or mm/dd/yyyy - depending on the setting for the
date display format)
Time display format
For specifying the time display format
34
When the floating NO contact is off (open contact)
When the floating NC contact is on (closed contact)
Set time / Set date / Time display format / Date display