3. PRE INSTALLATION CHECKS

3.1. Gate

The gate must be in good condition: ensure that its structure is suitable for
automatic control and that it conforms to the relevant standards.
The gate must remain horizontal throughout its travel, and must open and
close manually with ease.

3.2. Pillars

The pillars are out of plumb so require the use of an intermediate plate.
Furthermore, when one of the motor clamp mounting holes is not resting
on anything or is close to the angle of the pillar or wall, it is essential to
use the intermediate plate (ref. 2400485).

3.3. Reinforcements

If the gate has no reinforcements, fit some metal reinforcement plates
(e.g.: 15 x 15 cm and 4 cm thick) to secure the brackets to the gate leaves.

3.4. Field of application

This product is intended for the motorisation of a hinged gate for an indi-
vidual home.
H ≤ 2m

4. PREPARING AND DRILLING OF PILLARS

For the indicated values, the gate leaves and their hinge pins are taken to
be on the same axis.
If the hinge pins are offset, the maximum opening angle values will be
reduced.
1) Measure dimension A.
2) Select dimension B in the table according to the required opening an-
gle.
A (mm)
α max. (°)
0
50
100
150
200
250
5
P ≤ 200kg
B (mm)
120
205
110
160
105
150
100
150
95
150
90
150
90
150
90
150
3) Trace axis AM on the pillar copying dimension B onto the pillar.
4) Check that dimension D is greater than or equal to 435 mm.
There must be no obstacles to impede the movement of the arm in
this area.
5) Check that dimension L is between 1000 mm and 2000 mm.
If L < 1250, the installation of a set of photoelectric cells is essential.
6) Trace a horizontal axis AH in the middle of the reinforcement, perpen-
dicular to the rotational axis of the gate.
If the gate has no reinforcements, place the motors approximately
1/3 of the way up the gate leaves from the bottom.
Extend this line on the pillar until it intersects with AM.
7) Place the template where the 2 lines intersect and drill.
Axovia 220B RTS