LERICA C254 Mode D'emploi page 97

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Rev. 03 - 07/2015 - Cod. 1501151 - Instruction manual for vacuum chamber packaging machines Mod. C254-C308-C312-C412-C420
5) Cycle start-up.
Lower the lid using both hands by pres-
sing both corners of the lid.
The cycle starts automatically.
6) Moving to the next function in advance.
To move from the vacuum phase to the gas phase in advance or to move directly to the sealing phase, press
the corresponding vaC/GaS or SEal key.
7) Interrupting a cycle.
The machine immediately stops the cycle and the chamber is decompressed when the StOP button is
pressed at any time. The lid is opened automatically.
The machine returns to the set program
8) End of cycle.
The lid is opened automatically. Remove the packed product, paying attention not to touch the sealing bar,
which could still be hot.
97

Publicité

Table des Matières
loading

Produits Connexes pour LERICA C254

Ce manuel est également adapté pour:

C308C310C312C412C420

Table des Matières