3) Open the machine and access the power board, fol-
lowing the steps described in pt. 11.2.
4) Unscrew the protective lid from the power board (Fig.
1).
5) Identify the serial port for connection with the bootloader
located on the left side of the power board. Connect the
bootloader (fig. 2).
Fig. 1
6) Plug in the machine. Turn on the main switch of the machine to start programming. The green LED on the
bootloader blinks during data transfer. The green LED stops blinking when the data has been transferred,
and the control panel of the machine starts up.
7) Turn off the main switch and unplug the machine.
8) Disconnect the programming cable of the bootloader.
9) Put the protective cover back on the power board and fasten the screws.
1 0) Close the machine following chap. 11.3.