Assembly of the ultrasonic sen-
sor and its "optional
accessory supplied on request"
support for automatic width
measurement
- insert the ultrasonic sensor cable in the
slots on the metal pipe (see fig.6);
CAUTION
to facilitate the access of the cable in the
slots on the metal tube, it is advisable to
remove the tube from the rotation pin by
unscrewing the M12 screw present.
- fasten the ultrasonic sensor support to the
guard pipe using the three screws provided
(fig. 6a);
- connect the sensor cable to the connector
on the side of the casing (A, fig.6b)
- Adjust the length of the ultrasonic sensor
cable near the connector (A, fig.6b) with
protection closed, in order to avoid a
deformation of the connector during the
movement of the wheel guard.
- Then lock the cable using the supplied
clamp (A, fig.6). Any excess of the cable
in question must be inserted and locked
(using the bases already present) inside
the sensor support. To access the sensor
support, remove the plastic casing by
Operator's Manual S 65 E - S 65 E C
6b
6
6a
6c
79