- Using the Enter button
if it is in the following configuration:
- press
to confirm the selection made and exit the function.
WARNING:
The list of the configuration programmes can be displayed as follows:
- Select the utility and configuration programmes
- Select the configuration programmes
- Select view other icons
Calibrate when detecting that the setting condition is out-of-tolerance or when the machine
so requires as the E 1 message is displayed.
Calibrate as follows:
1.
select the sensitivity calibration icon
2.
fit a wheel of average dimensions (diameter no less than 14"), with preferably only
a small unbalance, on the wheel balancer;
3.
perform a spin;
4.
At the end of the spin, fix the calibration weight supplied with the machine on the
swinging unit bell as indicated in figure 26.
126
, select the desired mode. The selected icon is enabled
icon.
Sensitivity Calibration
in the configuration program menu
icon;
icon;
Operator's Manual S 65 E - S 65 E C