• Adhesive weights applied manually, without a weight-holder device ("CLIP adhesive
weight application position" enabled)
1 Select the first side to be balanced
2 Turn the wheel until the central element of the corresponding position indicator lights
up. Holding the wheel stationary with the clamping brake, move the sensor until the two
reference lines coincide in the relevant windows on the screen.
3 Manually apply the adhesive weight, taking the centre of the gripper cavity as the
reference for the midway point of the weight.
"Movable planes" programme (available only with ALU P
programmes and SELECTION POSITION APPLICATION ADHESIVE
This function is automatically enabled when an ALU P programme is selected.
It modifies the former selected positions for the application of adhesive balancing weights,
in order to allow perfect wheel balancing using commercially available adhesive weights
in multiples of five grams. The accuracy of the machine is thereby improved, avoiding
rounding-off or cutting the weights to be applied to come closer to the actual unbalance
values.
The modified positions, where the adhesive weights are to be applied, are identified
by the user according to the information given by the wheel balancer (see the Balancing
weight application section).
This programme divides the outer weight Pe into two weights, P1 and P2, located in any
position chosen by the operator.
The only condition is that the two weights must be within an angle of 120° (including the
weight Pe), as shown in fig. 22.
Figure 22. Conditions necessary for using the Hidden weights programme
The Hidden Weight programme is used on alloy rims, only and exclusively in conjunction
with the ALU 1P/ALU 2P programme:
- when the outer weight would rather be hidden behind two spokes for aesthetic rea-
104
WEIGHTS configuration CLIP)
"HIDDEN WEIGHTS" PROGRAMME
(available on with ALU P programme)
Operator's Manual S 65 E - S 65 E C
22