Section 4
Preventative Maintenance Cleaning
Procedure
This procedure cleans all components in the water flow
path, and is used to clean the ice machine between the
bi-yearly cleaning/sanitizing procedure.
Ice machine cleaner is used to remove lime scale and
mineral deposits. Ice machine sanitizer disinfects and
removes algae and slime.
NOTE: Although not required and dependent on your
installation, removing the ice machine top cover may
allow easier access.
Step 1 Ice must not be on the evaporator during the
clean/sanitize cycle. Follow one of the methods below:
•
Press the power switch at the end of a harvest cycle
after ice falls from the evaporator(s).
•
Press the power switch and allow the ice to melt.
! Caution
Never use anything to force ice from the evaporator.
Damage may result.
Step 2 Open the front door to access the evaporator.
Step 3 Press the Clean button. Water will flow through
the water dump valve and down the drain. Wait until the
water trough refills and the display indicates "Add
Chemical" (approximately 1 minute), then add the proper
amount of ice machine cleaner.
Model
I0300/I0320/I0520
I0450/I0500/I0600/I0850
I0900/I1000/I1100/I1200
I1400/I1800
Step 4 Select "Auto Ice On", press the Checkmark and
close and secure the front door. The ice machine will
automatically start ice making after the clean cycle is
complete (approximately 24 minutes).
Part Number 000007345 2/14
Amount of Cleaner
3 ounces (90 ml)
5 ounces (150 ml)
9 ounces (265 ml)
Door Removal
1. Use a phillips screwdriver to loosen the two screws
securing the door. Do not remove they are retained
to prevent loss.
2. Open left front door to 90 degrees. .
3
Door Removal
3. Support with right hand, depress top pin, tilt top of
door forward and lift out of bottom pin to remove.
Maintenance
1