Water-Cooled Condenser Water Pressure; Cooling Tower Applications (Water-Cooled Models) - Manitowoc Indigo Série Manuel D'installation, D'utilisation Et D'entretien

Masquer les pouces Voir aussi pour Indigo Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Section 2
Water Supply and Drain Line Sizing/Connections
! Caution
Plumbing must conform to state, local and national
codes.
Water
Location
Temperature
Ice Making
35°F (2°C) Min.
Water Inlet
90°F (32°C) Max.
Ice Making
Water Drain
Condenser
90°F (32.2°C) Max.
Water Inlet
Condenser
Water Drain
Bin Drain
Large Capacity
Bin Drain

WATER-COOLED CONDENSER WATER PRESSURE

Water pressure at the condenser cannot exceed 150
psig (1034 kPa) with the standard water-regulating
valve. Contact your distributor if your water pressure is
greater than 150 psig (1034 kPa). A special order
condensing unit is available that allows water pressure
up to 350 psig (2413 kPa)
COOLING TOWER APPLICATIONS
(WATER-COOLED MODELS)
A water cooling tower installation does not require
modification of the ice machine. The water regulator
valve for the condenser continues to control the
refrigeration discharge pressure.
It is necessary to know the amount of heat rejection, and
the pressure drop through the condenser and water
valves (inlet and outlet) when using a cooling tower on
an ice machine.
Part Number 000007345 2/14
Water Pressure
20 psi (140 kPa) Min.
80 psi (552 kPa) Max.
---
---
Standard
20 psi (140 kPa) Min.
150 psi (1034 kPa) Max.
High Pressure Option
20 psi (140 kPa) Min.
350 psi (2410 kPa) Max.
---
---
---
---
---
---
Ice Machine Fitting
3/8" (.95 cm) Female Pipe Thread
1/2" (1.27 cm) FPT I3300 Only
1/2" (1.27 cm) Female Pipe Thread
i0300 - i1200 = 3/8" Female Pipe Thread
i1400 - i1800 = 1/2" Female Pipe Thread
1/2" (1.27 cm) Female Pipe Thread
3/4" (1.91 cm) Female Pipe Thread
1" (2.54 cm) Male Pipe Thread
Water entering the condenser must not exceed
90°F (32°C).
Water flow through the condenser must not exceed
5 gallons (19 liters) per minute.
Allow for a pressure drop of 7 psi (50 kPa) between
the condenser water inlet and the outlet of the ice
machine.
Water exiting the condenser must not exceed
110°F (43°C).
The Commonwealth of Massachusetts requires that
all water-cooled models must be connected only to a
closed loop, cooling tower system.
Installation Instructions
Tubing Size Up to Ice
Machine Fitting
3/8" (.95 cm) min inside diameter
1/2" (1.27 cm) min inside diameter
1/2" (1.27 cm) min inside diameter
3/4" (1.91 cm) minimum inside
diameter
1" (2.54 cm) min. inside diameter
.
Important
15

Publicité

Chapitres

Table des Matières
loading

Table des Matières