8 MAINTENANCE
The MINIBENCH-MAXIPLUS does not require any
particular maintenance because the pins and sliding
surfaces operate on long-life self-lubricating bushes.You
are nevertheless advised to constantly monitor the lift and
take immediate action whenever faults, unusual wear or
breakage occur.

8.1 ROUTINE MAINTENANCE

CAUTION! The frequencies of the various
maintenance operations listed below are a
guide and refer to normal operating conditions.
Conditions can vary in relation to the type of
service, frequency of use and the amount of
dust in the environment. If the lift is used in
heavy duty conditions, maintenance must be
increased.
CAUTION! When topping up the level, changing
the oil or greasing, always use the same type
of lubricant previously used.The grease points
must be thoroughly cleaned with compressed
air before lubrication to prevent dust, dirt or
foreign bodies mixing with the lubricant.
ONCE A DAY:
Before starting work, check the operation of the
emergency stop button.
Check the correct operation of the ascent limit-switch
by running an ascent-descent cycle.
ONCE A WEEK:
Lubricate and grease the slide and hinge points by
means of the safety hook lubricator.
Check the oil level in the control unit tank: it must be
near the fi lling\control plug. If necessary, top up the
tank with hydraulic oil such as ESSO NUTO H 46 via
the fi lling\control plug hole.
For this operation you are always advised to use the
same type of oil. If you wish to use oil of the same type
but a different brand, you are advised to wait until the oil
change.
ONCE A MONTH:
Check the tightening of the foundation bolts.
Check the condition of the structures and parts of
the MINIBENCH MAXIPLUS subject to wear and if
necessary replace the worn or damaged parts.
Always use original spare parts.
ONCE EVERY TWO YEARS:
Change the system's hydraulic oil.
WARNING! Observe the laws in force in the
country where the machine is being used
as regards use and disposal of the products
employed for cleaning and maintenance of
the lift, following the directions given by the
manufacturer of such products.

8.2 EXTRAORDINARY MAINTENANCE

Extraordinary maintenance operations (repairs of parts or
components) must be performed only by skilled personnel
authorised by the manufacturer.
WARNING! If the lift is dismantled at the end of
its working life, observe the anti-pollution laws
in force in the country where the machine is
being used.
8.3 RECORDING THE MAINTENANCE
OPERATIONS
The routine and extraordinary maintenance operations
must be trancribed in the suitable recording check book.