(from 0 to 100) and confirm your setting by pressing the
START/SET key.
10.1.4 Selecting the Temperature Unit and Entering the Inventory
Number
The unit of temperature values (Centigrade or Fahrenheit)
can be selected in a sub-menu similar to the language
selection (see Sect. 10.1.1). The internal identifier of the
welding unit in its owner's inventory can be entered in the
same way as the commission number (see Sect. 6.2).

10.2 Understanding the "Recording" Sub-menu

"Welder Code on" means that the welder identification
code has to be entered as set with "Welder Code Op-
tions," "off," that this is impossible.
"Commission Number on" means that the commission
number (job number) will have to be entered or con-
firmed before every new welding, "off" that the user
is not prompted to enter it.
"Additional Data on" means that the additional data will
have to be entered or confirmed before every new
welding, "off" that the user is not prompted to enter
them.
"Fitting Code on" means that the second, so-called trace-
ability code of the electrofusion fitting has to be
entered before every welding, "off," that this is not
possible.
"Installing Company on" means that the company that
performs the installation work has to be entered before
every welding, "off," that this is not possible.
All data can also be read from a bar code with the
scanner, provided such a bar code is available.
Info
11

Self-Monitoring Functions Overview

11.1 Errors During Data Input

11.1.1 Code Error

An erroneous input has occurred, a code tag is poor or has
an error in code symbology or code reading was improper.

11.1.2 No Contact

There is no properly established electric contact between
the welding unit and the fitting (check push-on terminal
on fitting), or the heater coil is defective.
20
EN
HÜRNER HCU 300 User's Manual
H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
Data Recording
Welder Code
>Commission No.
Additional Data on
Data Recording
>Fitting Code
Installing Comp.off
Version March 2016
on
off
Display 20
on
Display 21