Entering The Fitting Traceability Code; Entering The Installing Company; Entering Welding Parameters Manually; Manually Entering Welding Voltage And Time - Hürner HCU 300 Manuel Utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6.4 Entering the Fitting Traceability Code

If this feature is enabled in the configuration menu, after
the fitting code was entered, another input "Fitting Code"
is required. This is the so-called "traceability code" or
"second fitting code" of the fitting.
This input is entered either from a bar code using the scan-
ner or manually using the alphanumeric keypad (see Info
in Sect. 5.2). Press the START/SET key to confirm your input.
If the code entered is not correct, a "Code Error" message
appears; check the string of numbers and correct as needed.
If the code entered is correct, it is saved to system memory
and inserted into the welding reports to be printed. By
pressing the STOP/RESET key, you skip this input.

6.5 Entering the Installing Company

In the same manner as the fitting traceability code (see
Sect. 6.4), entering a maximum of 15 characters for the
company that performs the installation or reading its name
from a bar code is possible, if this feature was enabled in
the configuration (see Sect. 10.2).
7

Entering Welding Parameters Manually

To be able to enter the welding parameters manually, you
have first to connect the fitting to the welding unit with
the welding cable. Manual parameter input can then be
accessed by pressing the ò arrow key. The screen will show
a menu as reproduced in Display 10, provided manual input
is enabled in the configuration menu (see Sect. 10.1).
Using the arrow keys ñ and ò you can select "Enter Volt-
age/Time" or "Enter Fitting Code" (i.e., the ordered string
of numbers that represents the fitting code). Confirm your
selection by pressing the START/SET key.

7.1 Manually Entering Welding Voltage and Time

If this option was chosen in the manual parameter input
menu, a display like the one to the right appears on the
screen. Use the alphanumeric keypad (see Info in Sect. 5.2)
to set the welding voltage and the welding time, accord-
ing to the fitting manufacturer's instructions, then press
the START/SET key to confirm your input. The "Start ?"
message displayed after the confirmation by START/SET
indicates that the unit is ready for welding.
14
EN
HÜRNER HCU 300 User's Manual
H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
*** Fitting Code ***
********************
******
**
Manual Input
Enter Voltage/Time
>Enter Fitting Code
Voltage/Time
U= 40 V
Version March 2016
Display 9
**
Display 10
t=
1000 s
Display 11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

200-230-115

Table des Matières