Circuit - Parker Compax3 I10T10 Manuel Technique

Pas/direction entrées analogiques
Masquer les pouces Voir aussi pour Compax3 I10T10:
Table des Matières

Publicité

Parker EME
3.10.4.3
Gerät 1
L1 ... L3
controller
3
L1
X1/1
L2
X1/2
L3
X1/3
Gerät 2
controller
3
L1
X1/1
L2
X1/2
L3
X1/3

Circuit:

I10T10:I0: X12/6
Energise
I11T11:I2: X12/8
I12T11:I0: X12/6
Feedback
Controller
Feedback
power
supply
O2: X12/4
K1
GND24V
safety
relay
Enable
X4/3
power
supply
X4/4
Feedback
X4/5
I10T10:I0: X12/6
Energise
I11T11:I2: X12/8
I12T11:I0: X12/6
Feedback
Controller
power
Feedback
supply
O2: X12/4
K2
GND24V
safety
relay
Enable
X4/3
power
supply
X4/4
Feedback
X4/5
K1
K2
Y39
Not-Aus-Modul
Emergency power-off modul
BH5928.47(Dold)
193-120100 N15 C3I10T10 Juin 2008
Kanal 1
Channel 1
4
4
Not-Aus- Schalter
57
13
S31
S21
Emergency
S11
power-off switch
S12
S22
S32
A1(+)
58
14
A2(-)
Y40
+24V
GND24V
Description d'appareils Compax3
motor
motor
Schutztür offen
Safety door open
S1
Gefahrenbereich
S2
Danger Zone
S13
S24
23
13
S23
2-kanaliger
Schutztürwächter
2-channel safety
door control
BD5985N(Dold)
24
14
Y1
Y2
A2(-)
GND24V
S14
A1(+)
+24V
79

Publicité

Table des Matières
loading