GB
PLACING INTO OPERATION
7
PLACING INTO OPERATION
7.1
INSTALLATION LOCATION
Position mortar spraying machine in a level position to
prevent it from sliding away.
7.2
COMPRESSOR (ACCESSORY)
Set up the compressor next to the mortar spraying
machine and connect to the mains.
7.3
CONNECTING MORTAR HOSE
• Check that the outlet unit (1, fig. 12) is seated firmly. If neces-
sary tighten star grips (2) by hand).
• Connect mortar hose (3) and secure with tension levers (4).
• Screw remote control to connection (5) on the control unit.
• Connect atomization air connection (6) on mortar hose to
the compressed air supply or compressor (accessory).
12
44
4
6
7.4
CONNECTING SPRAY LANCE WITH AUTOMATIC
SYSTEM
• Assemble texture nozzle (1, fig. 13) on the spray lance with
cone in the direction of the spraying head.
The nozzle size should be at least three times the grain
size,
e.g., grain size
• Connect spray lance (2) and secure with tension levers (3).
• Close material tap (4).
• Screw coupling plug (5) for remote control to the control ca-
ble of the mortar hose.
• Connect atomization air connection (6) to the air hose of the
mortar hose.
5
6
5
7.5
CONNECTING SPRAY LANCE WITHOUT
AUTOMATIC SYSTEM
• Fasten remote control switch (1, fig. 14) with the two O-rings
(2) to the mortar hose.
• Screw coupling plug (3) for remote control on the control
cable of the mortar hose.
• Assemble texture nozzle (4) on the spray lance with cone in
the direction of the spraying head.
The nozzle size should be at least three times the grain
size,
e.g., grain size
2
1
• Connect spray lance (5) and secure with tension levers (6).
• Close material tap (7).
• Connect atomization air connection (8) to the air.
3
Plast Coat 15
synthetic resin plaster
nozzle size
3
2
4
synthetic resin plaster
nozzle size
–>3 mm
–>10 mm
13
1
–>3 mm
–>10 mm