Télécharger Imprimer la page

Rohde ST 310 Mode D'emploi page 61

Masquer les pouces Voir aussi pour ST 310:

Publicité

5.3.3.
Firing program sequence
No.
Description
After the program delay t
1
elapsed, the firing program starts.
The temperature rises at the first
entered, ascending ramp rate
2
Rmp
until the first switch point
1
Tmp
.
1
After the first switch point, Tmp
the kiln continues with the second
entered, ascending ramp rate
3
Rmp
(heating up) until the kiln
2
reaches the end temperature,
Tmp
.
2
After reaching the end temperature
Tmp
, the kiln remains at this
2
4
temperature for the set soak
period t
.
2
The controller then executes the
5
cooling rate Rmp
3
the program is reached.
Remarks
has
0
If no program delay is entered, the firing program starts immediately.
⇒ The ramp rate is settable in the range between 1 °C/h and
999 °C/h or as FULL (full load heating) or END (program end).
⇒ If the entered temperature Tmp
chamber temperature, Rmp
skipped in the firing program when the program starts, and the
controller starts at the second heating rate, Rmp
,
1
⇒ The ramp rate is settable in the range between 1 °C/h and
999 °C/h or as FULL (full load heating) or END (program end).
⇒ The temperature is settable over the range of 0 °C to 1400 °C
(depending on the kiln model and its maximum temperature).
⇒ The soak period is settable over the range 00:00 (no soak) to 99
hours 59 mins.
⇒ During soaking, the controller display alternates every 15
seconds between kiln temperature and soak period remaining.
Last indicator light („Tmp
until the end of
indicates the end of the program.
59 / 384 - EN -
is lower than the current firing
1
and Tmp
are automatically
1
1
"): adjustable cooling temperature resp.
3
.
2

Publicité

loading