4.4.
Extension cable for the control unit
• If the bracket for the control unit is attached at the operation location (near the kiln or mounted on a wall), the
connecting cable can be extended using an extension cable.
• The extension cable for the control systems is optionally available in lengths of 2.5, 5 or a maximum of 10
metres.
• Note on extension cables and environmental influences due to EMC:
To meet the requirements for electromagnetic compatibility (EMC), the length of the controller
connection cable should not exceed 3 metres.
If the controller is connected to the kiln with an extension cable, it should be ensured that there is no
electrical device in the direct vicinity of the cable (electromagnetic stray field). Failure to do so could
result in a loss of temperature control accuracy of up to 3°C in the control system.
4.5.
Note on third-party kilns
The wiring of the mating CPC 14 socket on the kiln can vary between kiln manufacturers!
Attention!
If the assignments of the controller and kiln do not match, then there is a risk of damage to both the controller and
kiln.
5.
Operation & use
5.1.
General operation
5.1.1.
Switching the control unit on & off
The selector switch for switching the control unit on and off is located on the underside of the housing.
Switching the control unit on
Set the selector switch to
position "I".
Switching the control unit off
53 / 384 - EN -
Set the selector switch to
position "0".