Rizzoli RA Série Manuel D'utilisation page 73

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

A
Air intake external
B
Picture 13 - Rear sight of the plinth of the wood fired co-
oker and specifies for the connection with the
air intake through the plinth. The clear part
represents the standard opening in which you
can insert the pipe for the connection.
2.11
FIRE DOOR COOLING AIR
Inside the fire door there is a small air flow
that allows a better cooling of the fire door
itself. In this case, the air is always taken
from the room of installation. In case of in-
stallations with air intake directly connected
to the cooker, we suggest to close this air
flow through the regulator that is placed on
and under the fire door. The flow is open if
the regulator is in the position (+) and it is
closed if the regulator is in the position (-).
Usually this setting is done once during the
installation and then it is not modified dur-
ing the use.
H
C
B
Measures
Models
A
RA 45
97
RA 50
97
RA 60 SF
97
RA 60 CF
97
RA 70
97
RA 80
97
RA 90
97
RA 100
97
Table 2 - Dimensions for the connection of the external
air intake
Picture 14 - Regulation of the fire door cooling air
71
ø
B
C
H
46
350
253
95
46
400
253
95
46
500
253
95
46
500
253
95
46
600
253
95
46
700
253
95
46
800
253
95
46
900
253
95