Specifications and Characteristics
Specifications
Supplemental Characteristics
Common Characteristics
AC Input Efficiency, Power Factor, and THD
Output Impedance Graphs
Inductive Load Boundary for Constant Current (CC) Operation
Capacitive Load Boundary for Constant Voltage (CV) Operation
Measurement Accuracy and Resolution
Excessive Dynamic Protection
Output Quadrants
Specifications
Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 40°C
after a 30-minute warm-up. Specifications apply at the output terminals, with local sensing.
Specification
DC Ratings
   Voltage source:
   Current source and sink:
   Power:
Output ripple & noise
    CV peak-to-peak: 2
    CV rms: 3
Load regulation
    Voltage: 4
    Current:
Voltage programming &
measurement accuracy: 5
Current programming &
measurement accuracy: 5
Transient response 6
    Recovery Time:
    Settling band:
1 200/208 Vac input reduces the current and power rating 50%; 200/208 Vac input is only available with firmware rev B.06.03.1003 and up
2 From 20 Hz to 20 MHz (-3dB bandwidth) with resistive load, terminals ungrounded, or either terminal grounded
3 From 20 Hz to 10 MHz (-3dB bandwidth) with resistive load, terminals ungrounded, or either terminal grounded
4 Also applies when remote sensing with a ≤1 V drop per load lead - see
5 Percent of value + offset; at 25°C ±5°C after a 30 minute warm-up; measurement NPLC=1; valid for 1 year, see
with a ≤1 V drop per load lead - see
6 Recovery to within settling band following a step from 40%-90% and 90%-40% of full load at Comp 0, with a 40μs current rise and fall time
36
RP7972A
RP7973A
0 to 1000 V
0 to 2000 V
0 to ±60 A
0 to ±30 A
0 to ±20 kW
0 to ±20 kW
1.5 V
200 mV
400 mV
50 mV
100 mV
8 mA
0.04% + 75 mV
0.04% + 150 mV
0.03% + 6 mA
0.03% + 3 mA
300 µs
300 µs
10 V
Wire Size
for information about additional load lead voltage drop
Keysight RP7970 & RP7980 Series Operating and Service Guide
RP7982A
0 to 1000 V
0 to ±90 A 1
0 to ±30 kW 1
3 V
1.5 V
200 mV
50 mV
4 mA
12 mA
0.03% + 75 mV
0.03% + 9 mA
300 µs
20 V
10 V
Wire Size
and
Remote Sense Connections
RP7983A
RP7984A
0 to 2000 V
0 to 1500 V
0 to ±30 A 1
0 to ±60 A 1
0 to ±30 kW 1
0 to ±30 kW 1
3 V
2.25 V
400 mV
300 mV
100 mV
75 mV
4 mA
8 mA
0.03% + 150 mV
0.03% + 100 mV
0.03% + 3 mA
0.03% + 6 mA
300 µs
300 µs
20 V
15 V
for additional information
Calibration
Interval;