[SOURce:]VOLTage:SLEW[:IMMediate] <value>|MIN|MAX|INFinity
[SOURce:]VOLTage:SLEW[:IMMediate]? [MIN|MAX]
Sets the voltage slew rate. The slew rate is set in volts per second and affects all programmed voltage
changes, including those due to the output state turning on or off. The slew rate can be set to any
value between 0 and 9.9E+37. For very large values, the slew rate will be limited by the unit's listed
programming speed and bandwidth. Keywords MAX or INFinity set the slew rate to maximum.
Parameter
0 – 9.9E+37, *RST MAX
Sets the output slew rate to 5 V per second: VOLT:SLEW 5
The query returns the value that was sent. If the value is less than the minimum slew rate, the min-
l
imum value is returned. The resolution of the slew setting is the same as the minimum value. This
can be queried using VOLTage:SLEW? MIN. The exact value varies slightly based on calibration.
[SOURce:]VOLTage:SLEW:MAXimum 0|OFF|1|ON
[SOURce:]VOLTage:SLEW:MAXimum?
Enables or disables the maximum slew rate override. When enabled, the slew rate is set to its
maximum value. When disabled, the slew rate is set to the immediate value set by the VOLTage:SLEW
command. Use VOLTage:SLEW? MAX to query the maximum slew rate that was set.
Parameter
0|OFF|1|ON, *RST ON
Enable the maximum slew rate override: VOLT:SLEW:MAX ON
The VOLTage:SLEW:MAX command is coupled to the VOLTage:SLEW command. If
l
VOLTage:SLEW sets the rate to MAX or INFinity, VOLTage:SLEW:MAX is enabled. If the slew rate is
set to any other value, VOLTage:SLEW:MAX is disabled.
Keysight RP7970 & RP7980 Series Operating and Service Guide
5 SCPI Programming Reference
Typical Return
<max value>
Typical Return
0 or 1
239