            :PERiod <value>
      :FUNCtion
            :CURRent 0|OFF|1|ON
            :VOLTage 0|OFF|1|ON
      :SWEep
            :NPLCycles <value>
            :OFFSet
                  :POINts <value>
            :POINts <value>
            :TINTerval <value>
      :WHOur
            :RESet
      :WINDow
[:TYPE] HANNing|RECTangular
[SOURce:]
ARB
            :COUNt <value>|INFinity
            :CURRent
                  :CDWell
[:LEVel] <value>{,<value>}|<Block>
                        :DWELl <value>
                        :POINts?
            :FUNCtion
                  :TYPE CURRent|VOLTage
            :TERMinate
                  :LAST 0|OFF|1|ON
            :VOLTage
                  :CDWell
[:LEVel] <value>{,<value>}|<Block>
                        :DWELl <value>
                        :POINts?
[SOURce:]
CURRent
[:LEVel]
[:IMMediate]
[:AMPLitude] <value>
                  :TRIGgered
[:AMPLitude] <value>
            :BWIDth
                  :LEVel 0, <value>
            :LIMit
[:POSitive]
Keysight RP7970 & RP7980 Series Operating and Service Guide
Sets the external datalog integration time.
Enables/disables current measurements.
Enables/disables voltage measurements.
Sets the measurement time in number of power line cycles.
Defines the offset in a data sweep for triggered measurements.
Defines the number of points in a measurement.
Defines the time period between measurement samples.
Resets the accumulated watt-hour measurement.
Selects the measurement window.
Specifies the number of times the Arb repeats.
Specifies the level of each point in the Arb.
Specifies the dwell time of each point in the Arb.
Returns the number of points in the Arb.
Specifies either a voltage or current Arb.
Selects the output setting after the Arb ends.
Specifies the level of each point in the Arb.
Specifies the dwell time of each point in the Arb.
Returns the number of points in the Arb.
Sets the output current when in current priority mode.
Sets the triggered output current.
Sets the compensation frequency.