commeo initial operation/setting by radio
Note for settings under point 5.2.: The motor must be selected for this setting with a trans-
mitter in SELECT mode (Status LED flashes slowly in orange). After completing the setting,
the motor is still selected (see point 5.).
5.2.2. Manual setup-mode, deletion and manual setting of the end positions
in operation bottom position, top stop/release
When the movement is interrupted once, the system is in manual setup-mode.
Important: A limit stop for the upper end limit is necessary!
First the lower end limit has to be run-up to. From there move against the upper limit stop
without interruption.
Operation
6 s
or
3 s
or
Drive
Press the STOP button of the transmitter for 6 seconds.
The motor will switch to manual setting mode. Both
limit positions already set will be deleted.
Move the motor to the lower end position with the UP
or DOWN button.
STOP
Press the STOP button of the transmitter for 3 seconds.
The correct rotation direction assignment will be car-
ried out at the end of the end position setting.
Run against the limit stop at the top without stopping;
the motor stops automatically. The correct direction of
STOP
rotation assignment has been made. Perform a test run:
The motor moves up against the limit stop and relieves
shortly.
Note: The transmitter may not yet have been pro-
grammed. See point 5.2.4. to program a transmitter.