iveo initial operation/setting by radio
6.1. Limit position setting and programming the first transmitter
6.1.1. Semi-automatic setup-mode, deletion and semi-automatic setting of the end
positions
in operation bottom position, top stop/release
When the movement is interrupted twice during operation, the system is in semi-automatic
setup-mode. The motor will only find the upper end limit automatically.
Important: A limit stop for the upper end limit is necessary!
First the lower end limit has to be run-up to. From there move against the upper limit stop
without interruption, until the motor is automatically switched off.
Caution! Only connect the radio motor that you wish to program to the mains. It is not possi-
ble to program more than one motor at the same time.
Operation
or
or
1 s
Drive
Move the motor with the UP or DOWN button down-
wards to the requested lower end limit.
STOP
STOP
Run against the limit stop at the top without stopping;
the motor stops automatically. The correct direction of
STOP
rotation assignment has been made. Perform a test run:
STOP
The motor moves up against the limit stop and relieves
shortly.
Press the PROG button at the transmitter. The transmit-
ter is now permanently programmed.