commeo initial operation/setting by radio
5. commeo initial operation/setting by radio
commeo initial operation
The commeo initial operation is only possible using commeo transmitters. To com plete the
settings in the receiver, the receiver must be selected with a trans mitter in SELECT mode. In
SELECT mode, there is only one connection at a time to a re ceiver. Only this one can be
moved and set.
5.1. Selection of a receiver
By pressing the SELECT button for 3 seconds the transmitter will be put into the SELECT
mode. After the SELECT mode has been started, the status LED will start to flash quickly and
the transmitter will look for the receiver. The status LED being lit in green indicates that the
receiver has been found and the status LED will flash slowly in orange. The first receiver com-
pletes a brief confirmation run. If no receivers have been found this will be indicated by the
status LED being lit in red.
Receiver selection with non-programmed transmitter/initial operation
>1 s
or
Receiver selection with programmed transmitter
1. Select the transmitter channel on which the receiver is programmed.
2. Push the SELECT button at the transmitter for 3 seconds. The transmitter is in
SELECT mode.
3 s
Note: The receivers found by this method can now be found using another non- programmed
transmitter within 4 minutes. Press the SELECT button on the additional transmitter for 3 sec-
onds for this purpose. The transmitter is in SELECT mode. All settings can now be completed
with both transmitters.
1. Interrupt the voltage supply of the receivers for > 1 second.
The receivers can be found within the next 4 minutes.
2. Push the SELECT button at the transmitter for 3 seconds. The
transmitter is in SELECT mode.
3 s