iveo initial operation/setting by radio
6.1.2. Manual setup-mode, deletion and manual setting of the end positions
in operation bottom position, top stop/release
When the movement is interrupted once, the system is in manual setup-mode. The motor
will only find the upper end limit automatically.
Important: A limit stop for the upper end limit is necessary!
First the lower end limit has to be run-up to. From there move against the upper limit stop
without interruption, until the motor is automatically switched off.
Caution! Only connect the radio motor that you wish to program to the mains. It is not possi-
ble to program more than one motor at the same time.
Setting with trans-
mitter
6 s
or
3 s
or
1 s
Drive
Connect to power.
Press the UP and DOWN buttons at the transmitter at
the same time. The transmitter is temporarily pro-
grammed into the motor.
Press the STOP button of the transmitter for 6 seconds.
Move the motor to the lower end position with the UP
or DOWN button.
STOP
Press the STOP button of the transmitter for 3 seconds.
The correct rotation direction assignment will be car-
ried out at the end of the end position setting.
Move the motor with the UP or DOWN button against
the upper limit stop. The motor stops automatically and
STOP
relieves shortly.
Press the PROG button at the transmitter. The transmit-
ter is now permanently programmed.
57
EN