iveo initial operation/setting by radio
6.5. Adjusting the end limits by using the transmitter
Setup-mode can only be finished by programming both end positions. The transmitter assign-
ment is not affected by this. When setting the end positions, the motor is in the normal oper-
ating state again.
Put the motor into service mode by disconnecting it. Press the STOP button of an assigned
transmitter for 6 (manual setup-mode)/9 (automatic setup-mode) seconds to return the
motor to setting mode (wait until the transmitter indicator flashes twice/three times). Then
set the end positions as described in the grey sections for items 6.1.1. to 6.1.3.
Fuse/Hirschmann plug
3 s
3 s
3 s
6.6. Reprogramming if a transmitter is damaged or lost
Only use if a programmed transmitter is no longer available (damaged or lost)!
In order to program a new transmitter/channel, the receiver has to be put into reprogram-
ming mode by disconnecting it from the mains supply. Subsequently press the PROG button
of the new transmitter for 3 sec. All the old transmitters/channels have been deprogrammed.
Fuse/Hirschmann plug
3 s
3 s
6.7. Resetting to the delivery status
To return the motor to the state at delivery, the motor must be brought into service mode by
disconnecting it. Then press the PROG button of an assigned transmitter for 9 seconds.
The motor will then have no transmitters or limit positions saved.
Fuse/Hirschmann plug
3 s
3 s
Assigned transmitter
STOP
6 s
or
STOP
9 s
New transmitter
3 s
3 s
Assigned transmitter
3 s
9 s
60
Set the end positions as de scribed
in the grey sections for items 6.1.2.
and 6.1.3.
Set the end positions as de scribed
in the grey sections for item 6.1.1.