iveo initial operation/setting by radio
6.8. Group separation
A group is an assembly of several motors/receivers that can be controlled by one transmitter/
channel. This transmitter is deleted after the end of the group separation. During group sepa-
ration, each motor/receiver will only once move randomly for 3 seconds within a period of
time of approx. 2 minutes. Stopping the motor with any transmitter will programm this trans-
mitter into the respective motor.
First press the STOP button and then the UP and DOWN buttons as well. Keep all three but-
tons pressed for 9 seconds, in order to start the group separation (wait until the transmitter
control light flashes three times). The motor indicates activation of group separation by a
short run. Then each motor will move randomly for 3 seconds within a period of about 2 min-
utes. Within the 3-second time slot, stop the movement of the motor using the STOP button
on the transmitter to be programmed. Then the transmitter is programmed, and the motor
has left the group separation mode.
Fuse/Hirschmann plug
3 s
3 s
Window 1
Window 2
3 s
Transmitter 1
Transmitter 2
If the motors are still moving together, repeat the procedure for the motors affected.
If you did not programm a transmitter through the STOP button and no other trans mitter is
programmed, you may programm this transmitter again by pressing the UP and DOWN but-
tons at the same time and then pressing the PROG button.
6.9. Changing the radio system to commeo
To change the radio system of a motor with iveo transmitters, first set the motor to service
mode and then select the motor using a commeo transmitter by pressing the SELECT button
for 3 seconds. When the motor has been selected, all iveo transmitters have been re-pro-
grammed.
Fuse/Hirschmann plug
3 s
3 s
3 s
Window 3
3 s
3 s
Transmitter 3
3 s
9 s
Every motor moves randomly only for
3 seconds within about 2 minutes. The
motor in question must be stopped by the
selected transmitter during the move-
ment.