E-PAK 150 DX/300 DX/500 DX
10.6.1
Ordering spare parts
See www.nederman.com.
When ordering spare parts always state the following:
Part number and control number, see the product identification plate.
Detail number and name of the spare part, see www.nederman.com.
Quantity of the parts required.
11
Recycling
The product has been designed for component materials to be recycled.
Its different material types are to be handled according to relevant local
regulations. Contact the distributor or Nederman with any queries about
scrapping the product at the end of its service life.
12
Troubleshooting
WARNING!
Use proper protective equipment when risking exposure to the dust.
WARNING!
Work with electric equipment is to be carried out by a qualified electrician.
WARNING!
Always disconnect the supply voltage with the maintenance switch before any
service, whether mechanical or electrical. Always lock the maintenance switch
in the off position.
WARNING!
Ensure that there is no vacuum present in the system during service.
WARNING!
Always disconnect the compressed air supply before any service.
WARNING!
Personnel operating E-PAK 150 DX/300 DX/500 DX is to pay special attention
to avoiding discharge of static electricity. The requirements for the safe use
and handling of combustible dust is described in the explosion protection
document. All personnel is to be informed.
WARNING!
Stop operation and clean the entire filter thoroughly from dust before any
grinding, welding or other hot works are performed on the filter exterior or
inlet.
If the trouble shooting guide in 'Table 12-1: Trouble shooting guide' does not
solve the problem, contact your nearest authorized distributor or Nederman for
technical advice.
46
All manuals and user guides at all-guides.com
Risk of personal injuries.
Risk of electric shock.
Risk of electric shock.
Risk of personal injuries.
Risk of personal injuries.
Risk of explosion.
Risk of explosion.

Publicité

loading

Ce manuel est également adapté pour:

E-pak 150 dxE-pak 500 dx