EN
E-PAK 150 DX/300 DX/500 DX
5.2
5.3
5.3.1
E-PAK 150 DX
Operating air flow at
110 m³/h (64.7 cfm)
15 kPa
Filter area: main filter/
3.4/1.5 m
control filter
Filter material: main
Conductive polyester/polyester
filter/control filter
Ambient temperature
-10–+40 °C (14–104 °F)
Process air
0–60 °C (32–102 °F)
temperature
Compressed air:
•
requirements
6–10 bar (87–145 PSI)
•
consumption
0.5 NL (0.13 gal)/cleaning pulse
Dimension, inlet
Flanged Ø 100 mm (3.937 in)
Dimension, outlet
Ø 105 mm (4.13 in)
Collector volume
50 litres (13.21 gal)
Weight
209 kg (460.8 lb)
Dimensions
See Section 5.2 Dimensions
Material recycling
Approximately 95 percent per weight
Sound level
<70 dB(A)
5.3.2
30
All manuals and user guides at all-guides.com
Figure 4 shows the function of E-PAK 150 DX/300 DX/500 DX according to
the following:
1.
Air flow during normal operation and collection of dust.
2.
Air with atmospheric pressure released into the filter during filter cleaning.
3.
Short blast of reversed air flow during filter cleaning.
4.
Filter cleaning valve.
Dimensions
For the dimensions of E-PAK 150 DX/300 DX/500 DX, see Figure 1, Figure 2
and Figure 3.
Technical and electrical data
Technical data
Table 5-1: Technical data contains technical data for the E-PAK DX high
vacuum units.
Figure 25 shows the fan characteristics diagram.
Table 5-1: Technical data
E-PAK 300 DX
290 m³/h (107.7 cfm)
(36.6/16.1 sqft)
3.4/1.5 m
2
Conductive polyester/polyester
-10–+40 °C (14–104 °F)
0–60 °C (32–102 °F)
6–10 bar (87–145 PSI)
0.5 NL (0.13 gal)/cleaning pulse
Flanged Ø 100 mm (3.937 in)
Ø 105 mm (4.13 in)
50 litres (13.21 gal)
250 kg (551.2 lb)
See Section 5.2 Dimensions
Approximately 95 percent per weight
<70 dB(A)
Electrical data
'Table 5-2: Electrical data' contains electrical data for the E-PAK DX high
vacuum units. For the location of the motor and starter cable areas (items Z, V
and X in the table), see Figure 22 and Figure 24.
E-PAK 500 DX
500 m³/h (942 cfm)
(36.6/16.1 sqft)
3.4/1.5 m² (36.6/16.1 sqft)
2
Conductive polyester/polyester
-10–+40 °C (14–104 °F)
0–60 °C (32–102 °F)
6–10 bar (87–145 PSI)
0.5 NL (0.13 gal)/cleaning pulse
Flanged Ø 100 mm (3.937 in)
Ø 105 mm (4.13 in)
50 litres (13.21 gal)
335 kg (734 lb)
See Section 5.2 Dimensions
Approximately 95 percent per weight
<70 dB(A)