setting =30 seconds.
For details about fuses and settings for the overload relay, see
Section 5.3 Technical and electrical data.
6.2
Accessories
The installation of Nederman accessories for E-PAK 150 DX/300 DX/500 DX
is described in the manuals for each product. Consult your local Nederman
representative for available accessories.
The E-PAK 150 DX/300 DX/500 DX start and control unit is prepared for
the connection of external accessories or signals. The signals/accessories
are connected according to the electric circuit diagram, see Figure 23
(E-PAK 150 DX) and Figure 24 (E-PAK 300 DX/500 DX). See also
'Table 6-1: Accessory terminals'.
The most common accessory is a PS cable which allows remote start/stop
signalling from the valves of the duct system.
Table 6-1: Accessory terminals
Terminal
Accessory/function description
1–2
Permanent 24 V AC of external equipment
3–4
Pilot signal
5–6
Remote start/stop
9–10
Compressed Air Switch (CAS)
11–12
External emergency stop
23–24
Remote run indicator
25–26
Remote alarm output (red fault indicator light)
7
Before installation
WARNING!
Risk of personal injuries.
Always use proper lifting and protective equipment.
WARNING!
Risk of tipping.
Consider the centre of gravity and attachments during transport.
NOTE!
Always follow local regulations and legislation for all steps of the
installation process.
NOTE!
Fill in the installation protocol during installation, see
'Appendix A: Installation protocol'.
NOTE!
Make a layout for the entire system before installing
E-PAK 150 DX/300 DX/500 DX.
7.1
Delivery checks
Check the unit for any transport damage. In case of damage or parts missing,
notify the carrier and your local Nederman representative immediately.
E-PAK 150 DX/300 DX/500 DX
EN
33