All manuals and user guides at all-guides.com
10.2
Checks one month after installation and every year
WARNING!
Risk of electric shock.
Always disconnect the supply voltage with the maintenance switch before any
service, whether mechanical or electrical. Always lock the maintenance switch
in the off position.
WARNING!
Risk of personal injuries.
Ensure that there is no vacuum present in the system during service.
WARNING!
Risk of personal injuries.
Always disconnect the compressed air supply before any service.
One month after installation, and then every year, perform the following
checks:
Check all power conductor and ground wire connections. Tighten, if required,
to ensure good contact.
Inspect the integrity of the dust separator.
Ensure that the inside of the unit and the connection ducts are free from
deposits. Build-up of deposits inside the duct system may cause discharge of
static electricity.
Clean the area around the unit and all areas where the collected material is
stored to ensure that there are no dust deposits.
Ensure that there is not any combustible material in the risk area.
Check that all signs/markings regarding safe operation are in place and that the
personnel knows about them.
10.3
Emptying the collector bin
WARNING!
Risk of personal injuries.
Ensure that there is no vacuum in the dust separator before removing the
collector bin.
WARNING!
Risk of personal injuries.
Crush hazard. Pay attention when lowering and refitting the collector bin. Use
proper protective equipment.
WARNING!
Risk of personal injuries.
Wear a protective mask.
The antistatic plastic bag is to be replaced when filled up to 2/3.
NOTE!
Use Nederman antistatic plastic bags only.
To replace the antistatic plastic bag:
1.
Check that the risk area is clear.
2.
Ensure that there is no vacuum in the dust separator.
3.
Remove the collector bin.
4.
Seal and remove the antistatic plastic bag. Use a cable tie or equivalent,
see Figure 13.
5.
Fit a new antistatic plastic bag in the collector bin.
6.
Refit the collector bin onto the dust separator.
E-PAK 150 DX/300 DX/500 DX
EN
43