Illustration 3:
4.2
Important
A
E
G
Connection panel Impression S models
A: power connection 100 – 240 V
AC, 50/60 Hz including glass fuse
T6,3A L250V
B: main power switch
C: optional Ethernet connection
D: USB connection
E: switching output for external pump
of the wet grinding module
Setting up the machine
Only use original cables from vhf to connect devices via the two switching
outputs (see Illustration 3). If you are using a different USB cable than the one
that is delivered, pay attention that it's not longer than 3 meters!
M 1. Unwrap the milling machine. Please keep the packaging for possible
further service shipments.
M 2. Connect the service unit via the standard pneumatic connection with
your compressed air supply (see also chapter 4.3).
Original Instructions: S2 Impression
Document version: F – 07/2019
Installation: Setting up the machine
B
C
D
F
H
I
F: switching output for external air
extraction unit
G: pneumatic connection, Ø 6 mm,
max pressure. 8 bar
H: liquid connection for external
pump of the wet grinding module,
Ø 6 mm, max. pressure 3 bar
I:
air extraction connection
19