8.3 Configuration 3 - Storage tank with serpentine

Sonda puffer
8
1
8
Componenti compresi nella stufa
Set configuration 3 when you intend to connect
the appliance to a storage tank with serpentine.
The appliance is controlled (switched on and
off) by the temperature read by the storage tank
probe in order to keep the storage tank at the
right temperature. When the set storage tank
temperature is reached, the stove switches off
and switches on again if the temperature falls
below the set delta.
The antifreeze function can also be set in this
configuration.
004778730 - 24/06/2021
T
1
ITALIANO
Pannello solare
5.1.12
Storage tank with serpentine electrical
connection
In this case simply move the room temperature
probe on the appliance and extend it to place it
in the probe seat, found on the storage tank (Fig.
31).
Storage tank probe
1
8
It is important to check that the appli-
ance is set to Configuration 3.