Electrical connection to a room
thermostat
The external thermostat must be connected
to the two terminals used for the room probe,
located on the rear of the appliance. Disconnect
the probe and connect the two contacts of the
thermostat (Fig. 29).
8
1
After installing the thermostat the ap-
pliance must be switched on manually.
The thermostat must be in the "call"
state to start the appliance. This opera-
tion is also necessary in the event of an
electricity supply failure or if the appli-
ance is turned off manually.
It is important to check that the appli-
ance is set to Configuration 1.