Description
PCB unit Polytron 8310
4-20/HART Relay
17.4.1 DSIR sensors
Description
DrägerSensor IR NPT
Sensing head, DrägerSensor
IR
complete set e
Sensing head, DrägerSensor
IR
complete set e2
®
17.5 Polytron
87x0 IR
Description
Polytron 87x0 PCB unit
1)
4-20/HART
Polytron 87x0 PCB unit
1)
4-20/HART relay
PIR 7000 attachment set
PIR 7000 process cuvette,
stainless steel
PIR 7000 SGR process
cuvette
PIR 7000 / 7200 status indi-
cator
PIR 7000 / 7200 splash
guard
PIR 7000 / 7200 flowcell
PIR 7000 / 7200 remote test
adapter
PIR 7000 insect protection
PIR 7000 hydrophobic filter
PIR 7000 adjustment adapter 6811610
PIR 7000 / 7200 POM pro-
cess adapter (polyoxymethy-
lene)
PIR 7000 assembly set
Terminal box Ex e
Terminal box Ex d
Magnetic wand
1) Check firmware compatibility of sensor and gas detector. Changing
the PCB unit may require a firmware update. Contact Dräger for sup-
port.
Instructions for use
|
Dräger Polytron
Part Number
4544789
Part number
6811901
6811165
6811265
Part number
4544795
4544796
6811648
6811415
6813219
6811625 / 6811920
6811911 / 6811912
6811490 / 6811910
6811630 / 6811930
6811609
6811890
6811915
6811648
6811989
4520561
4544101
®
8000 Series SW version ≥ 4.0.x
17.5.1 Sensors
Check firmware compatibility of sensor and gas detector.
Changing the sensor may require a firmware update. Contact
Dräger for support.
Description
Dräger PIR 7000 type 334
(NPT)
Dräger PIR 7000 type 340
(NPT)
Dräger PIR 7000 334 (M25)
complete set
Dräger PIR 7000 340 (M25)
complete set
Dräger PIR 7200 (NPT)
Dräger PIR 7200 (M25)
HART
complete set
18
Performance Approvals
In combination with certain sensors, Polytron 8xx0 is
performance approved based on the following standards:
– EU and Type Examination Certificates in line with
EN 6009-29-1, EN 50014, EN 45544 and EN IEC 62990-
1. Issued by DEKRA Testing and Certification GmbH,
Handwerkstr. 15, D-70565 Stuttgart.
– FM performance approval in line with ANSI/ISA-92.00.01
FM6340
For further information on sensor specifications and
restrictions (e.g., measuring principles, performance, cross-
sensitivity), refer to the instructions for use for the relevant
sensor.
18.1 EU-TYPE Examination Certificate,
BVS 13 ATEX G 001 X
Measurement of flammable gases and vapors mixed with air.
– Polytron 8200 CAT with DrägerSensor DQ
Special conditions:- When streaming with air containing
measured gas, measured values may increase by up to
32%.- Measured values may increase by up to 70% for
operation with the DQ remote calibration adapter.
– Polytron 8200 CAT with DrägerSensor LC
Approved with 10 %LEL full scale deflection.
A connection to a controller with approved measuring
function (e.g., REGARD
alarms for over range measured values must be activated
at the controller.
– Polytron 8310 IR with DrägerSensor IR
– Polytron 8700 IR with PIR 7000 type 334 and 340
Measurement of oxygen (inertization)
– Polytron 8100 EC with DrägerSensor O
DrägerSensor O
LS (6809630) within a measuring range
2
of 0-5...25 Vol% O
.
2
Performance Approvals
Part number
6811822
6811832
6811825
6811819
6811572
6812290
®
7000) is required. Latching
(6809720) and
2
|
en