Dräger Polytron 8000 Serie Notice D'utilisation page 15

Masquer les pouces Voir aussi pour Polytron 8000 Serie:

Publicité

Les langues disponibles

Les langues disponibles

The cable lengths are calculated for 2 standardized cables of
different quality:
– Tinned copper wire, class 5/6 in acc. with IEC 60228 /
VDE 0295
Characteristic cable resistance: 41 ohms/km at 20 °C
(134514 ohms/feet at 68 °F)
– Bare copper wire, class 2 in acc. with IEC 60228 /
VDE 0295
Characteristic cable resistance: 36 ohms/km at 20 °C
(118110 ohms/feet at 68 °F)
Polytron 8200 CAT DQ: 4 to 20 mA interface
Tinned copper wire, class 5/6 in acc. with IEC 60228 / VDE
0295
Values include a safety margin of 10 %.
Operating voltage: 24 V
AWG
21
20
0.5
0.75
2
mm
122 °F
Feet
925
1391
50 °C
m
282
424
68 °F
Feet
1033
1555
20 °C
m
315
474
Bare copper wire, class 2 in acc. with IEC 60228 / VDE 0295
Values include a safety margin of 10 %.
Operating voltage: 24 V
AWG
21
20
0.5
0.75
2
mm
122 °F
Feet
1030
1516
50 °C
m
314
462
68 °F
Feet
1683
1693
20 °C
m
513
516
Polytron 8200 CAT LC: 4 to 20 mA interface
Tinned copper wire, class 5/6 in acc. with IEC 60228 / VDE
0295
Values include a safety margin of 10 %.
Operating voltage: 24 V
AWG
21
20
0.5
0.75
2
mm
122 °F
Feet
906
1361
50 °C
m
276
415
68 °F
Feet
1014
1519
20 °C
m
309
463
Instructions for use
|
Dräger Polytron
18
16
13
1
1.5
2.5
1857
2710
4521
566
826
1378
2077
3028
5056
633
923
1541
18
16
13
1
1.5
2.5
2050
3068
5010
625
935
1527
2293
3429
5600
699
1045
1707
18
16
13
1
1.5
2.5
1814
2651
4423
553
808
1348
2031
2963
4944
619
903
1507
®
8000 Series SW version ≥ 4.0.x
Bare copper wire, class 2 in acc. with IEC 60228 / VDE 0295
Values include a safety margin of 10 %.
Operating voltage: 24 V
AWG
21
20
0.5
0.75
2
mm
122 °F
Feet
4902
3002
50 °C
m
1494
915
68 °F
Feet
1129
1657
20 °C
m
344
505
Polytron 8310
Max. 30 m
Polytron 87x0
Max. 30 m
6
Commissioning
6.1
General information
– Before connecting the instrument to the power supply,
connect the wires for the relay and connect up the sensor.
– Before starting normal operation of the instrument, check
whether the configuration and adjustment settings are
correct.
In order to guarantee its safe operation according to
BVS 13 ATEX G 001 X and PFG 14 G 001 X, the following
standard alarm settings for the instrument must remain
unchanged.
– The relays must be set to Normally energ. and the
alarm A2 (main alarm) to Latching and Non-
acknowledgeable or Pre-Acknowledgeable.
– Alarm A1 (pre-alarm) may only be set to
Acknowledgeable if used for activation of an acoustic
alarm device.
– Latching in the event of over range (see "Setting the DQ
sensor latching", page 38).
Commissioning
|
en
18
16
13
1
1.5
2.5
2008
1483
1007
612
452
307
2244
3356
5479
684
1023
1670
15

Publicité