14.3.3 Polytron 8100 EC with Dräger SensorAlive
Menu
Default setting
DSA warn current
2.0 mA
DSA warn limit
Depending on sen-
sor
DSA activation
On
LifeTest
Time
Depending on sen-
sor
Output behav-
Fixed
ior
Repeat profile
Flexible
Cancel thresh-
Depending on sen-
old
sor
Senor monitoring
Activation
Depending on sen-
sor
Alarm <50 %
Off
Alarm <40 %
DSA warning
Fault detection
On
14.3.4 Polytron 8200 CAT DrägerSensor
Menu
Default setting
Alarm A1
20 %LEL
Alarm A2
40 %LEL
Hysteresis for
1 %LEL
alarm A1 with
increasing direc-
tion
Hysteresis for
1 %LEL
alarm A2 with
increasing direc-
tion
Adjustment inter-
180
val [days]
Display capture
0 %LEL
range offset
Display capture
-5 %LEL
range low
Display capture
2 %LEL
range high
Full scale value
100 %LEL
Instructions for use
|
Dräger Polytron
Range
0 mA to 3.5 mA
On / Off
Fixed/mainte-
nance/measured
value
Flexible/static
Off/warning
Off/DSA warn-
ing/error
On / Off
®
DQ
Range
1 to 100 %LEL
0 to A1
0 to A2
0 to 360
-5 to 4 %LEL
-5 to 0 %LEL
0 to 4 %LEL
Not possible to set
range
®
8000 Series SW version ≥ 4.0.x
14.3.5 Polytron 8200 CAT DrägerSensor
Menu
Default setting
Alarm A1
2.0 %LEL
Alarm A2
4.0 %LEL
Hysteresis for
0.1 %LEL
alarm A1 with
increasing direc-
tion
Hysteresis for
0.1 %LEL
alarm A2 with
increasing direc-
tion
Full scale value
10 %LEL
Adjustment inter-
180
val [days]
Display capture
0 %LEL
range offset
Display capture
-0.5 %LEL
range low
Display capture
0.2 %LEL
range high
1) For firmware versions < 3.0.0
14.3.6 Polytron 8310 IR
Menu
Default setting
Alarm A1
20 %LEL
Alarm A2
40 %LEL
Hysteresis for
1 %LEL
alarm A1 with
increasing direc-
tion
Hysteresis for
1 %LEL
alarm A2 with
increasing direc-
tion
Adjustment inter-
180
val [days]
Display capture
0 %LEL
range offset
Display capture
-3 %LEL
range low
Display capture
2 %LEL
range high
Full scale value
100 %LEL
Factory default settings
|
®
LC
Range
0.1 to 10 %LEL
0 to A1
0 to A2
1)
5 to 10
% LEL
1 to 10 %LEL
0 to 360
-0.5 to 0.4 %LEL
-0.5 to 0 %LEL
0 to 0.4 %LEL
Range
1 to 100 %LEL
0 to A1
0 to A2
0 to 360
-3 to 4 %LEL
-3 to 0 %LEL
0 to 4 %LEL
Not possible to set
range
en