Télécharger Imprimer la page

Keysight E36731A Manuel D'instructions page 36

Publicité

Les langues disponibles

Les langues disponibles

Front view
Fasten the two screws at both side of the binding post (see below) to secure binding post to the front panel.
Recommended torque 9 lb-in (1 N-m).
Rear outputs connections
SHOCK HAZARD
Turn off AC mains before connecting wires to the rear panel. All wires and straps must be properly connected
with the terminal block screws securely tightened.
SHOCK HAZARD
Floating voltage must not exceed 240 V
must not be more than 240 V
DO NOT REMOVE THE MATING CONNECTOR
Rear output terminal connection must be performed with the presence of mating connector.
The mating connector accepts wires sizes from AWG 14 to AWG 6. The mating connector is 60 A rated for the
E36731A. Wire sizes smaller than AWG 14 are not recommended. Connect the DUT wires to the + and - terminals.
Connect the sense wires to the +s and -s terminals.
Securely fasten all wires by tightening the screw terminals.
Part number information for the connector kit is provided under
36
Side view
. The total voltage on the output terminal and the floating voltage
DC
from chassis ground.
DC
Standard Shipped
Items.
Keysight E36731A User's Guide

Publicité

loading