User Codes - Sygonix 1559246 Notice D'emploi

Serrure à code en acier surfin
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

e) User codes
The combination lock can store up to 110 user codes (100 codes for output #1 and 10 codes
for output #2).
The following section provides an introduction on how to use codes to enable the combination
lock outputs (e.g. to release a door opener), including a number of examples.
We recommend that you create a table to record all access data (including code num-
bers, user codes and user names for outputs #1 and #2).
This will help you to monitor registered users and access permissions.
It will also make it easier to delete users and the corresponding user codes.
Saving a user code:
• The combination lock must be in programming mode (see section 12. a) for details).
• Enter the programming code for output #1 or #2:
Output 1
Output 2
• Enter a memory number.
.....
.....
• Enter the desired 4 - 8 digit user code.
Important!
When the "Auto entry" feature is enabled (see section 12. m), all codes must be the
same length (e.g. if the master code is 5 digits, the user codes must also be 5 digits).
• Press the
button to confirm your entry. The combination lock will beep twice and the mid-
dle LED will flash two times to indicate that the code has been saved.
• You can now create another user (press number
#2).
• When you have finished adding all users, press
12. a) for details).
82
100 user codes for output 1
10 user codes for output 2
for output #1 or number
to exit programming mode (see section
for output

Publicité

Table des Matières
loading