Conversion to a Different Type of Gas
Before converting the appliance for operation with a different gas type, check which type of gas it is currently set to operate with
(adhesive label (Figure 1) on appliance).
Disconnect the electrical power supply to the appliance; For the correct nozzle diameter, refer to the relative table in this booklet.
Nozzle Table
The diameters in hundredths of millimetre are stamped on the nozzle.
Top burner
Nominal heat input
kW
Inner ring injector
size
Outer ring injector
size
Consumption
Gas family
Gas
Gas pressure
mbar
AT
BE
BG
CH
CY
CZ
DE
DK
EE
ES
FI
FR
GB
GR
HU
IE
IS
IT
LT
LU
LV
MT
NL
NO
PL
PT
RO
SE
SI
SK
AL
HR
MK
TR
8 - Conversion to a Different Type of Gas
4,50
37
98
328 g/h
328 g/h
3+
"G30 G31"
"G30 G31"
"28...30 37"
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
LP
4,50
4,50
37
34
98
94
328 g/h
3B/P
3B/P
"G30 G31"
30
37
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
EN
4,50
32
90
328 g/h
3B/P
"G30 G31"
50
x
x
x
x
15

Publicité