To conserve the motion detector's battery life, if the motion detector transmits two open zone signals (LED on for 3s)
within a five-minute period, the detector will fall into Energy Save Mode for approximately three minutes and will not
transmit any alarm signals. The red LED will continue to flash to indicate a detection. If the detector's cover is removed
and then replaced while in Energy Save Mode, the first detection will trigger an alarm signal.
Walk-testing
To activate Walk-test Mode for three minutes, power up the detector or open and close the detector's cover. With
sensitivity set to High (S2 = High), at 20°C, crossing more than one complete zone (consisting of two beams left and
right sensor detecting elements) with slow/fast walking or running should initiate an alarm. With sensitivity set to Low
(S2= Low), the amount of movement required to generate an alarm is doubled.
Beam Pattern
16m
14m
12m
10m
8m
6m
4m
(52.5ft)
(45.9ft)
(39.4ft)
(32.8ft)
(26.3ft)
(19.7ft)
(13.1ft)
2.1m
(6.8ft)
0
2m
4m
6m
(6.6ft)
(13.1ft)
(19.7ft)
(26.3ft)
88.5°
2m
0
2m
4m
6m
8m
10m
12m
(6.6ft)
(6.6ft)
(13.1ft)
(19.7ft)
(26.3ft)
(32.8ft)
(39.4ft)
8m
10m
12m
14m
16m
(39.4ft)
(32.8ft)
(45.9ft)
(52.5ft)
Specifications
Sensor Type
Coverage
Pet Immunity
RF Frequency
Lens
Walk Speed
Battery Type & Life
Current Rating
Transmitter Range
Operating Temp. &
Humidity
Dimensions & Weight
RF Immunity
Compatibility
Certification
* Battery life expectancy will vary according to the amount of traffic (movement) detected. Higher traffic levels will lower battery life.
14m
16m
(45.9ft)
(52.5ft)
Warranty: For complete warranty information on this product, please refer to the Limited Warranty Statement found on the Web site www.paradox.com/terms. Your use of the Paradox
product signifies your acceptance of all warranty terms and conditions.
© 2013 Paradox Ltd. All rights reserved. Specifications may change without prior notice.
Patents: One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111, and RE39406 and other pending patents
may apply. Canadian and international patents may also apply.
Dual rectangular element
88.5° - 11m (36ft) x 11m (36ft); Center beams: 15m (49ft)
18kg (40lbs)
433 or 868 MHz with Magellan only
2nd generation Fresnel lens, LODIFF® segments
0.2m to 3.5m/s (0.6ft to 11.5ft/s)
3 x 1.5vDC "AAA" alkaline batteries; 2 years*
31uA standby / 15mA alarm
35m (115ft) with MG6130 / MG6160
70m (230ft) with MG5000 / MG5050 / RTX3; in a typical residential environment
0°C to 50°C (32°F to 122°F) / 5 to 90% max.
6.5 x 12.5 x 5.2cm (2.5 x 4.9 x 2.0 in) / 105 g (3.7 oz) with batteries
EN 50130-4: 10V/m 80MHz to 2.7GHz
See paradox.com for compatibility details
EN 50131 Grade 2 Class II; Certification body Intertek
PMD2P-EI01 - Printed in Canada 06/2013