Changing The High-Pressure Hose - Truma MonoControl Mode D'emploi

Masquer les pouces Voir aussi pour MonoControl:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

MonoControl
Fig� 7
4.3.2
Gas cylinder with clip-on adapter
For handling the clip-on adapter, see the operating instructions for
the clip-on adapter�
Close the valve from the clip-on adapter�
Disconnect the clip-on adapter from the empty gas cylinder�
If a gas filter is present, change the filter pad (see the operating
instructions for the gas filter)�
Replace the gas cylinder�
Connect the clip-on adapter to the full gas cylinder�
Open the valve from the clip-on adapter�
If available, press the hose rupture protection on the high-pres-
sure hose�
If necessary, press the black reset button on the gas pressure
regulator and gently turn in an anti-clockwise direction�
After any intervention, check the hose connection on the cylinder
valve for leaks (see the "Checking for leaks in the high-pressure
section" chapter)�
4.4

Changing the high-pressure hose

Gas cylinders in different countries have a wide range of connections�
This may lead to the high-pressure hose also needing to be changed
when a gas cylinder is changed�
Truma offers a multitude of high-pressure hoses for different Euro-
pean gas cylinders (see www�truma�com)�
50020-00982 ∙ 00 ∙ 08/2022