Operation instructions

Taking into operation

Open gas remote switch if
present.
1. Open extraction valve.
2. Press gas flow monitor reset
button (green button) on gas
pressure regulator slowly.
3. Release gas flow monitor
reset button (green button) on
gas pressure regulator slowly
(3 seconds).
3.
3 sec
2.
If no pressure point can be felt
when the button is pressed
again, the regulator is ready for
operation (repeat procedure if
necessary).
Start the gas-burning devices if
desired.
The SecuMotion may switch off
if it is not going to be used for
a long period and the extraction
valve is closed.
Checking for leaks in the
high pressure area
A trained technician must
check the low pressure
area for leaks. We also recom-
1.
mend that the operator of the
gas system should check the
high-pressure area for leaks
(screw connections at extraction
valve / regulator inlet) at regular
intervals.
Using a leak spray, for ex-
ample, in accordance with
DIN EN 14291.