Product description
3.2
Gas pressure regulator
The MonoControl gas pressure regulator is a safety gas pressure
regulator according to EN 16129 for operation with liquid gas in the
gas phase�
3.3
PRV
The gas pressure regulator is fitted with an automatic safety device
(PRV)
� If the gas pressure regulator is not working properly, for
1)
example due to dirt or other foreign mateiral, the safety valve opens
and releases the overpressure� The connected consumers are thus
protected from an impermissibly high pressure� The PRV closes auto-
matically after the pressure is reduced�
PRV = Pressure Relief Valve
1)
3.4
Reset button
The gas pressure regulator has a reset button� It is only needed for
the gas check�
If the black reset button is pushed in (Fig� 2-1), the gas pressure
regulator is ready for operation� This means that the gas system is
supplied with gas�
If the black reset button is protruding (Fig� 2-2), the gas pressure
regulator is not ready for operation� This means that the gas system is
not supplied with gas�
Fig� 2
Unusually strong vibrations while driving may lead to the reset
button triggering inadvertently� In this situation, the flow of gas is
interrupted� To reset the reset button, see chapter „Resetting the
reset button")
40 EN
1
MonoControl
2
50020-00982 ∙ 00 ∙ 08/2022