Maintenance - Truma MonoControl Mode D'emploi

Masquer les pouces Voir aussi pour MonoControl:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

MonoControl
Disconnect the low-pressure section from the high-pressure sec-
tion� To do this, use the T20 Torx pin of the screw aid to turn the
black reset button in a clockwise direction until the reset button
jumps out�
Unscrew the screw cap of the test connection�
Connect the regulator test appliance with the test hose to the test
connection�
Check for leaks in accordance with the national regulations
(e�g� 607 in Germany)�
Unscrew the regulator test appliance from the test connection�
Screw the screw cap back onto the test connection�
Press the black reset button with the T20 Torx pin of the screw aid
in the housing and gently turn in an anti-clockwise direction�
Abb� 8
1
Screw aid with Torx pin T20
2
Reset button
3
Screw cap
6

Maintenance

The gas pressure regulator is maintenance-free�
Do not remove covers on the gas pressure regulator under any
circumstances�
If in doubt, contact Truma Service�
50020-00982 ∙ 00 ∙ 08/2022
2
1
Maintenance
3
EN
49

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ce-0085ct0438Monocontrol csDuocontrol cs

Table des Matières