MonoControl
Loosen the high-pressure hose from the gas pressure regulator
or gas filter� Use the supplied screw aid (width across flat 23 mm)
for this purpose� Use a spanner (width across flat 18 mm) to hold
the gas pressure regulator in place�
Check the new high-pressure hose for contaminants� Clean the
high-pressure hose if necessary�
Check the flat gasket for dirt or damage� Replace the flat gasket if
necessary�
Insert the flat gasket accurately into the hose connection�
Screw the new high-pressure hose onto the gas pressure
regulator or gas filter� Use the supplied screw aid (width across
flat 23 mm) for this purpose� Use a spanner (width across
flat 18 mm) to hold the gas pressure regulator in place� Use your
hand to hold the gas filter in place�
If the screw aid jumps over or slips during tighening, the required
tightening torque has been reached�
If present, attach the clip-on adapter back onto the high-pressure
hose�
Screw the high-pressure hose onto the cylinder valve of the full
gas cylinder with the screw aid�
Open the cylinder valve of the gas cylinder�
If available, press the hose rupture protection on the high-pres-
sure hose�
If necessary, press the black reset button on the gas pressure
regulator and gently turn in an anti-clockwise direction�
After any intervention, check the high-pressure hose connection
on the cylinder valve for leaks (see the "Checking for leaks in the
high-pressure section" chapter)�