Operation
High-pressure hoses must be replaced before their expiry date
elapses or when they are damaged�
Store high-pressure hoses in a dark and dry place�
Observe national and local regulations�
Use the supplied screw aid to change the high-pressure hose�
The required tightening torque is achieved with the screw aid�
Damage to the bolted connections caused by unsuitable tools is
thus avoided�
Never use hose clips because this can cause damage and leaks in
high-pressure hoses�
WARNING
Risk of fire and explosion hazard due to residual gases
Residual gases may escape and form a flammable gas mix-
ture with the air when the high-pressure hose is changed�
Do not use any naked flames or open fire�
Do not smoke�
WARNING
Risk of fire and explosion hazard due to damaged or
missing seal
Check the flat gasket during each high-pressure hose
change and replace it if it is ageing, hardening, cracking
or exhibits other visible defects�
Never use self-made seals; instead, only use Truma
original spare parts�
Ensure that the seal is available and properly installed�
It is advisable to replace the flat gasket G�13 (see chapter
„Accessories") during each hose change�
Close the cylinder valve of the gas cylinder�
Disconnect the high-pressure hose from the cylinder valve or clip-
on adapter� Observe the direction of rotation (left-hand thread)�