11.3.4 Error type E or F
1
2
3
4
9a
9b
Fig. 48: Error type E, flowchart
1
2
3
4
5
Fig. 49: Error type F, flowchart
6.0.0.0
E000
Fig. 50: Acknowledging error type E or F
92
Error type E (Fig. 48):
5
6
7
8
Error type F (Fig. 49):
If type E or F errors occur, proceed as follows to acknowledge (Fig. 50):
• To change to menu mode, press the red button.
Menu number <6.0.0.0> flashes on the display.
12.3
• Press the red button again.
The error is acknowledged, and the status page is displayed.
NOTE:
The error will be acknowledged automatically if the cause of the error
is eliminated.
Program
Contents

step/query

1

• Error code is displayed

• Pump goes into emergency operation
2

• Error meter is incremented

3
Error matrix AC or HV?
4

• SSM is activated

5
Error criterion fulfilled?
6

Error acknowledged?

7
Error matrix HV and > 30 minutes?
8
• SSM is activated
9a
End; auto control (double pump) resumes
9b
End; auto control (single pump) resumes
Yes
No
Program
Contents
step/query
1
• Error code is displayed
2
• Error meter is incremented
3
Error criterion fulfilled?
4
Error acknowledged?
5
End; auto control resumes
Yes
No
WILO SE 05/2010